TotalApp Docs

Mining & Natural Resources — Safety & Ground Control

Monitor slopes, ground support, ventilation, dams and exposure, control blast exclusion zones, keep rescue readiness and watch operator fatigue — specific to mining operations.

What this group covers

Eight screens for safety processes that exist only in mining. Everyone with a mining role can see them (except the fatigue log, below); each step is offered only to people holding its capability and the system stamps who took it.

Where SafetyOps stays in charge

Incidents, near-misses, general OH&S training and corrective-action (CAPA) management belong to SafetyOps. Nothing here duplicates them: a record can carry a SafetyOps reference, and that reference is one-way — Mining points to SafetyOps, never the other way around.

ScreenRecordsWho responds
Ground Control / Slope StabilityPrism, radar, extensometer, piezometer and support readingsSafety responder acknowledges
Ventilation MonitoringAir velocity and gas readingsSafety responder clears emergencies
Blast Safety & Exclusion ZonesExclusion zone per blast, sentry posts, violationsEvacuation approver
Mine Rescue & Emergency ResponseRescue teams, equipment readiness, drills—
Dust, Noise & Vibration ExposureMeasurements against limitsSafety responder opens and closes actions
Tailings Dam MonitoringPond level, freeboard, displacement, factor of safetySafety responder acknowledges
Subsidence & Convergence MonitoringStation readings and ratesSafety responder acknowledges
Vehicle Interaction & FatigueOperator shifts, breaks, collision-avoidance alertsFatigue reviewer

Ground Control, Dam and Convergence monitoring

Each reading belongs to a monitoring point or station. The screens calculate the movement rate (change per day against the previous reading of the same point) and an alert level — normal, alert or critical — from the thresholds you enter on the reading. Ground control and dam thresholds are on the cumulative value, factor of safety and freeboard; convergence and subsidence thresholds are on the daily rate. A banner counts open alerts. The Trend tab charts the selected point over time with its thresholds as dashed lines.

ScreenLevels
Ground ControlAlert and critical on cumulative displacement (mm)
Tailings DamAlert below the alert factor of safety or minimum freeboard; critical below the critical factor of safety or half the minimum freeboard
Convergence / SubsidenceAlert and critical on the rate (mm/day); the first reading of a station has no rate

A critical reading can be acknowledged only by a safety responder and needs a written note. Subsidence and convergence stations are kept in one screen.

Ventilation Monitoring

Record air velocity, oxygen, carbon monoxide, methane and carbon dioxide per station. The limits are on the reading and default to common values (0.3 m/s, 19.5 % O₂, 30 ppm CO, 1 % CH₄, 0.5 % CO₂) — set them to your jurisdiction’s limits.

Emergency trigger

A reading outside any limit becomes an Emergency automatically and stays open until a safety responder clears it with a written reason. Correcting a reading back inside the limits returns it to normal. The trigger is written to the audit trail.

Blast Safety & Exclusion Zones

A zone is prepared for a blast event from Production & Extraction: radius, sentry posts and the evacuation plan. The radius cannot be smaller than the exclusion radius on the blast event, only planned or cleared blasts can get a zone, and a blast has one active zone. The Zone map tab draws the radius and sentry posts schematically. After approval, violations are reported with a note and the number of violations; the zone is closed after the all-clear.

Who approves

The person who prepared the zone cannot approve the evacuation. The server refuses and records the attempt.

Mine Rescue & Emergency Response

Keep rescue teams (trained members), rescue equipment (readiness) and emergency drills. Each record has a readiness status and a next check or drill date; overdue items are flagged and appear on the calendar. Readiness changes are edited on the record and kept in its change history. Completing a drill or retiring a record is recorded with who and when.

Dust, Noise & Vibration Exposure

Enter a measurement with its limit. A value above the limit sets the record to Action required. Add the SafetyOps CAPA reference, open the corrective action with a written description, and close it with a written outcome. The CAPA itself is managed in SafetyOps; here you keep only the reference.

Vehicle Interaction & Fatigue Management

Log each operator’s shift: hours worked, break time, rest since the previous shift and collision-avoidance alerts. A shift is flagged when it is longer than the maximum, rest is shorter than the minimum, or a shift of six hours or more has too short a break — the limits are on the record (12 h, 8 h and 30 min by default). A reviewer reviews each log and must add a note when a rule was broken.

Personal shift data

The fatigue log is visible only to people with a fatigue capability. Operators are picked from staff; no health data is recorded.

Frequently Asked Questions

Where do I record an accident or near-miss?
In SafetyOps. Mining keeps only a reference on the monitoring record.
Why did a reading become an Emergency by itself?
Ventilation readings outside any limit raise an emergency automatically. A responder clears it with a reason, or correct the reading if it was a typing error.
Why is there no rate on a reading?
The rate needs an earlier reading of the same point or station.
Why can I not approve the evacuation?
Segregation of duties: the person who prepared the zone cannot approve it.